Induction Motor Number of pole pairs |
![]() |
The structure column shows the same value in code. Each element of the structure is presented as a list. For example the value shown in the left picture is written as:
Motor PowerRatingPlate NumberOfPolePairs | Switching
Configuration name | Structure name | Constant | Par ID | Note |
---|---|---|---|---|
Induction Motor Nominal speed |
Motor PowerRatingPlate NominalSpeed |
MOTOR_SPEED_RATED | 50 | |
Induction Motor Nominal frequency |
Motor PowerRatingPlate NominalFrequency |
MOTOR_FREQ_RATED | ||
Induction Motor Nominal voltage |
Motor PowerRatingPlate NominalVoltage |
MOTOR_VOLTAGE_RATED | 48 | |
Induction Motor Nominal current |
Motor PowerRatingPlate NominalCurrent |
MOTOR_CURR_RATED | 57 | |
Induction Motor Power Factor |
Motor PowerRatingPlate PowerFactor |
MOTOR_POWER_FACTOR | ||
Induction Motor Nominal ambient temperature |
Motor PowerRatingPlate NominalAmbientTemperature |
MOTOR_AMB_TEMP_RATED | 865 | |
Induction Motor Optional Parameters Number of pole pairs |
Motor PowerRatingPlate OptionalParameter NumberOfPolePairs |
MOTOR_POLEPAIRS | 47 | |
Induction Motor Optional Parameters Maximum speed |
Motor PowerRatingPlate OptionalParameter MaximumSpeed |
MOTOR_SPEED_MAX | 51 | |
Induction Motor Optional Parameters Stall current |
Motor PowerRatingPlate OptionalParameter StallCurrent |
MOTOR_CURR_STALL | 56 | |
Induction Motor Optional Parameters Peak current |
Motor PowerRatingPlate OptionalParameter PeakCurrent |
MOTOR_CURR_MAX | 58 | |
Induction Motor Optional Parameters Magnetizing current |
Motor PowerRatingPlate OptionalParameter MagnetizingCurrent |
MOTOR_MAGNETIZING_CURR | 59 | |
Induction Motor Optional Parameters Nominal Power |
Motor PowerRatingPlate OptionalParameter NominalPower |
MOTOR_POWER_RATED | ||
Induction Motor Optional Parameters Nominal torque |
Motor PowerRatingPlate OptionalParameter NominalTorque |
MOTOR_TORQ_RATED | 53 | |
Induction Motor Optional Parameters Stall torque |
Motor PowerRatingPlate OptionalParameter StallTorque |
MOTOR_TORQ_STALL | 52 | |
Induction Motor Optional Parameters Peak torque |
Motor PowerRatingPlate OptionalParameter PeakTorque |
MOTOR_TORQ_MAX | 54 | |
Induction Motor Optional Parameters Moment of inertia |
Motor PowerRatingPlate OptionalParameter MomentOfInertia |
MOTOR_INERTIA | 62 | AS uses kgcm2 PAR ID uses kgm2 |
Induction Motor Temperature sensor Limit temperature |
Motor PowerRatingPlate TemperatureSensor Thermistor LimitTemperature |
MOTOR_TEMPSENS_LIM | 1216 | Thermistor |
Induction Motor Temperature sensor Temperature sensor interface |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureSensorInterface |
Thermistor | ||
Induction Motor Temperature sensor ResistanceR0 |
Motor PowerRatingPlate TemperatureSensor Thermistor ResistanceR0 |
MOTOR_TEMPSENS_PAR1 | 64 | Thermistor |
Induction Motor Temperature sensor ResistanceR7 |
Motor PowerRatingPlate TemperatureSensor Thermistor ResistanceR7 |
MOTOR_TEMPSENS_PAR2 | 65 | Thermistor |
Induction Motor Temperature sensor TemperatureT0 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT0 |
MOTOR_TEMPSENS_PAR3 | 66 | Thermistor |
Induction Motor Temperature sensor TemperatureT1 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT1 |
MOTOR_TEMPSENS_PAR4 | 67 | Thermistor |
Induction Motor Temperature sensor TemperatureT2 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT2 |
MOTOR_TEMPSENS_PAR5 | 68 | Thermistor |
Induction Motor Temperature sensor TemperatureT3 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT3 |
MOTOR_TEMPSENS_PAR6 | 69 | Thermistor |
Induction Motor Temperature sensor TemperatureT4 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT4 |
MOTOR_TEMPSENS_PAR7 | 70 | Thermistor |
Induction Motor Temperature sensor TemperatureT5 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT5 |
MOTOR_TEMPSENS_PAR8 | 71 | Thermistor |
Induction Motor Temperature sensor TemperatureT6 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT6 |
MOTOR_TEMPSENS_PAR9 | 72 | Thermistor |
Induction Motor Temperature sensor TemperatureT7 |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureT7 |
MOTOR_TEMPSENS_PAR10 | 73 | Thermistor |
Induction Motor Temperature sensor Temperature sensor interface |
Motor PowerRatingPlate TemperatureSensor Thermistor TemperatureSensorInterface |
Switching PTC thermistor |
||
Induction Motor Temperature sensor Nominal response resistance |
Motor PowerRatingPlate TemperatureSensor SwitchingPTCThermistor NominalResponseTemperature |
MOTOR_TEMPSENS_PAR1 | 64 | Switching PTC thermistor |
Induction Motor Temperature sensor Minimum resistance |
Motor PowerRatingPlate TemperatureSensor SwitchingPTCThermistor MinimumResistance |
MOTOR_TEMPSENS_PAR2 | 65 | Switching PTC thermistor |
Induction Motor Temperature sensor TemperaNominal response temperature |
Motor PowerRatingPlate TemperatureSensor SwitchingPTCThermistor NominalResponseTemperature |
MOTOR_TEMPSENS_PAR3 | 66 | Switching PTC thermistor |
Induction Motor Temperature sensor Temperature sensor interface |
Motor PowerRatingPlate TemperatureSensor Thermoswitches TemperatureSensorInterface |
Thermoswitches | ||
Induction Motor Temperature sensor Nominal response resistance |
Motor PowerRatingPlate TemperatureSensor Thermoswitches NominalResponseTemperature |
MOTOR_TEMPSENS_PAR1 | 64 | Thermoswitches |
Induction Motor Temperature sensor Minimum resistance |
Motor PowerRatingPlate TemperatureSensor Thermoswitches SwitchingStateOnOvertemperature |
MOTOR_TEMPSENS_PAR10 | 73 | Thermoswitches |
Induction Motor Temperature model Current-based Limit temperature |
Motor PowerRatingPlate TemperatureModel CurrentBased LimitTemperature |
MOTOR_WIND_TEMP_MAX | 74 | Current-based |
Induction Motor Temperature model |
Motor PowerRatingPlate TemperatureModel |
TEMP_MOTOR_MODEL_MODE | 373 | Current-based Current- and speed-based |
Induction Motor Temperature model Current-based Winding cross section |
Motor PowerRatingPlate TemperatureModel CurrentBased WindingCrossSection |
MOTOR_WIND_CROSS_SECT | 59 | Current-based |
Induction Motor Temperature model Current-based Thermal tripping time |
Motor PowerRatingPlate TemperatureModel CurrentBased ThermalTrippingTime |
PIDENT_THERM_TRIP_TIME | 1283 | Current-based |
Induction Motor Temperature model Current-based Thermal time constant |
Motor PowerRatingPlate TemperatureModel CurrentBased ThermalTimeConstant |
MOTOR_TAU_THERM | 849 | Current-based |
Induction Motor Temperature model Current- and speed-based Limit temperature |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased LimitTemperature |
MOTOR_WIND_TEMP_MAX | 74 | Current- and speed-based |
Induction Motor Temperature model Current- and speed-based Calculation method Winding cross section |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod SecondOrderThermalNetwork WindingCrossSection |
MOTOR_WIND_CROSS_SECT | 74 | Current- and speed-based Second-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal tripping time |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod SecondOrderThermalNetwork CalculationMethod SecondOrderThermalNetwork ThermalTrippingTime |
PIDENT_THERM_TRIP_TIME | 1283 | Current- and speed-based Second-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal time constant |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod SecondOrderThermalNetwork ThermalTimeConstant |
MOTOR_TAU_THERM | 849 | Current- and speed-based Second-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal resistance 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork ThermalResistance1 |
MOTOR_TEMPMODEL_RES1 | 1211 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal capacity 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork ThermalCapacity1 |
MOTOR_TEMPMODEL_CAP1 | 1212 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal resistance 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork ThermalResistance2 |
MOTOR_TEMPMODEL_RES2 | 1213 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal capacity 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork ThermalCapacity2 |
MOTOR_TEMPMODEL_CAP2 | 1214 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Stator thermal loss 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork StatorThermalLoss1 |
MOTOR_TEMPMODEL_LOSS1 | 1489 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Stator thermal loss 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork StatorThermalLoss2 |
MOTOR_TEMPMODEL_LOSS2 | 1490 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Winding thermal loss 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork WindingThermalLoss1 |
MOTOR_TEMPMODEL_LOSS1_W | 1654 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Winding thermal loss 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderThermalNetwork WindingThermalLoss2 |
MOTOR_TEMPMODEL_LOSS2_W | 1655 | Current- and speed-based Fourth-order thermal network |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal resistance 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ThermalResistance1 |
MOTOR_TEMPMODEL_RES1 | 1211 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal capacity 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ThermalCapacity1 |
MOTOR_TEMPMODEL_CAP1 | 1212 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal resistance 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ThermalResistance2 |
MOTOR_TEMPMODEL_RES2 | 1213 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal capacity 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ThermalCapacity2 |
MOTOR_TEMPMODEL_CAP2 | 1214 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Thermal resistance 3 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ThermalResistance3 |
MOTOR_TEMPMODEL_RES3 | 1653 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Stator thermal loss 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings StatorThermalLoss1 |
MOTOR_TEMPMODEL_LOSS1 | 1489 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Stator thermal loss 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings StatorThermalLoss2 |
MOTOR_TEMPMODEL_LOSS2 | 1490 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Winding thermal loss 1 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings<br/WindingThermalLoss1 |
MOTOR_TEMPMODEL_LOSS1_W | 1654 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Winding thermal loss 2 |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings WindingThermalLoss2 |
MOTOR_TEMPMODEL_LOSS2_W | 1655 | Current- and speed-based Fourth-order thermal network with couplings |
Induction Motor Temperature model Current- and speed-based Calculation method Reference Temperature Temperature offset |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ReferenceTemperature EncoderTemperatureSensor TemperatureOffset |
MOTOR_TEMPMODEL_REF_OFF | 1706 | Current- and speed-based Fourth-order thermal network with couplings Reference Temperature Encoder temperature sensor |
Induction Motor Temperature model Current- and speed-based Calculation method Reference Temperature Time constant |
Motor PowerRatingPlate TemperatureModel CurrentAndSpeedBased CalculationMethod FourthOrderWithCouplings ReferenceTemperature EncoderTemperatureSensor TimeConstant |
MOTOR_TEMPMODEL_REF_TAU | 1707 | Current- and speed-based Fourth-order thermal network with couplings Reference Temperature Encoder temperature sensor |
Induction Brake Nominal current |
Brake Used NominalCurrent |
MOTOR_BRAKE_CURR_RATED | 42 | |
Induction Brake Nominal torque |
Brake Used NominalTorque |
MOTOR_BRAKE_TORQ_RATED | 43 | |
Induction Brake Activation delay |
Brake Used ActivationDelay |
MOTOR_BRAKE_ON_TIME | 44 | |
Induction Brake Release delay |
Brake Used ReleaseDelay |
MOTOR_BRAKE_OFF_TIME | 45 | |
Induction Brake Moment of inertia |
Brake Used MomentOfInertia |
MOTOR_BRAKE_INERTIA | AS uses kgcm2 PAR ID uses kgm2 |
|
Induction Brake Control mode |
Brake Used ControlMode |
Voltage controlled | ||
Induction Brake Control mode Release voltage |
Brake Used ControlMode VoltageControlled ReleaseVoltage |
MOTOR_BRAKE_VOLT_REL | 1504 | Voltage controlled |
Induction Brake Control mode Hold voltage |
Brake Used ControlMode VoltageControlled HoldVoltage |
MOTOR_BRAKE_VOLT_HOLD | 1505 | Voltage controlled |
Induction Brake Limits Maximum voltage |
Brake Used Limits Used MaximumVoltage |
MOTOR_BRAKE_VOLT_MAX | 1506 | Voltage controlled |
Induction Encoder Proof of fatigue strength |
MOTOR_ENCOD_ATTR | 652 | ||
Induction Encoder Moment of inertia |
Encoder Used MomentOfInertia |
MOTOR_ENCOD_INERTIA | AS uses kgcm2 PAR ID uses kgm2 |
|
Induction Encoder Temperature sensor Limit temperature |
Encoder Used TemperatureSensor Used LimitTemperature |
MOTOR_ENCOD_TEMP_LIM | 1209 | |
Induction Gearbox Gear ratio input |
Gearbox Used GearRatio |
Only one value in code | ||
Induction Gearbox Gear ratio output |
Gearbox Used GearRatio |
Only one value in code | ||
Induction Gearbox Maximum input speed |
Gearbox Used MaximumInputSpeed |
MOTORGEAR_SPEED_MAX | 1695 | |
Induction Gearbox Nominal output torque |
Gearbox Used NominalOutputTorque |
MOTORGEAR_TORQ_NOM | 1693 | |
Induction Gearbox Peak output torque |
Gearbox Used PeakOutputTorque |
MOTORGEAR_TORQ_MAX | 1694 | |
Induction Gearbox Moment of inertia |
Gearbox Used MomentOfInertia |
MOTORGEAR_INERTIA | AS uses kgcm2 PAR ID uses kgm2 |